Heating and spa

The controller heats the pool and the spa to separate target temperatures using whichever heat sources are selected: a pool heater, a spa heater (or one combined heater) and solar. Which heat source runs at a given moment is the controller’s decision; the API sets the targets and the selection.

GET…/temperatureInfo

{
"status": "SUCCESS",
"data": {
"temperatureInfo": {
"temperature": [
{
"category": "pool",
"solar_temp": 2450,
"water_temp": 265,
"target_temp": 28,
"is_solar_heater_selected": false,
"is_pool_heater_selected": true,
"is_spa_heater_selected": false,
"is_solar_heater_on": false,
"is_pool_heater_on": true,
"is_spa_heater_on": false
},
{
"category": "spa",
"solar_temp": 2450,
"water_temp": 265,
"target_temp": 38,
"is_solar_heater_selected": false,
"is_pool_heater_selected": true,
"is_spa_heater_selected": false,
"is_solar_heater_on": false,
"is_pool_heater_on": true,
"is_spa_heater_on": false
}
],
"is_mp_en": true,
"temp2_ch": 0,
"temp3_ch": 0
}
}
}
Field Meaning
category pool or spa. Only target_temp differs between the two entries; the readings and the selection are shared
target_temp Target temperature for that category, whole °C
water_temp Current water temperature, °C × 10
solar_temp Roof or air sensor, °C × 100
is_*_selected The heat sources the controller may use
is_*_on The heat source outputs energised right now. is_pool_heater_on and is_spa_heater_on are both true when a combined pool and spa heater is on
is_mp_en, temp2_ch, temp3_ch Sensor configuration set at commissioning: whether the chemistry probe is enabled and which input each extra temperature sensor uses. Read-only in practice; see below

This read is cached like the others (see How reads work). The cached copy expires after 10 minutes.

POST…/setTemperatureInfo

{
"desire_pool_temp": 28,
"desire_spa_temp": 38,
"is_solar_heater_selected": false,
"is_pool_heater_selected": true,
"is_spa_heater_selected": false
}
Field Type Range Meaning
desire_pool_temp int 0 to 40 Pool target, whole °C
desire_spa_temp int 0 to 40 Spa target, whole °C
is_solar_heater_selected bool Allow solar heating
is_pool_heater_selected bool Allow the pool heater
is_spa_heater_selected bool Allow the spa heater

The controller replaces all five values with what you send and any field you omit becomes 0 or false, so read temperatureInfo first and send the complete set. Values outside the range return 400 with a message such as desire_pool_temp must be 0-40 (got 45). The API carries the controller’s sensor configuration (temp2_ch, temp3_ch) across unchanged; do not send those fields unless SplashMe support asks you to.

Response: 200 with data.message holding the controller’s acknowledgement string. The write waits up to 3 seconds and clears the cached temperatureInfo and dashboardInfo. Changing the selection while the pump is running takes effect at once; otherwise it applies when the pump next runs.

Spa mode is not a setting: it is the state of the spa actuator outputs. Switch any spa actuator slot (type 20, 21, 33 or 34, listed in auxInfo.spa) with manualSet and the controller moves all of them together, starts the main pump at the spa speed and heats towards desire_spa_temp with the spa heater. Switching any of them off ends spa mode and clears the pump override that spa mode held. auxInfo shows the actuators’ aux_status and dashboardInfo.spa_heater_state shows whether the spa heater is on.

Heater cool-down after a spa or heating session is described under Manual overrides.